Asbestos Awareness Training

iata300From £375

Face-Fit Testing

Fit2Fit Tests

logo fit2fit september 17 2

 

Non Licenced Removal Training

iata300From £575+vat

Call us to see how we can help

Call 0845 259 1149

Qualitative Face-Fit Testing


Reasons to use Fire Coral...
  • IATP Asbestos Awareness Training from £375+vat for 20 delegates
  • On-site face-fit testing from as little as £195+vat for up to 20 tests.
  • Asbestos Removal Training (Non-Licensed) from £575+vat
  • Immediate certification if you've paid up-front.
  • Face-fit testing of up to 40 people per day

Like to speak to someone? Call us on 0845 259 1149

requestNLAAC

requestSession


On Site Face Fit Testing Company In Cambridgeshire


>If you require Face-fit testing for your company staff and are based in the Cambridgeshire area, Fire Coral Ltd can provide fully trained members to come out to your place of work and provide qualitative face-fit testing for your employees. Health and Safety at work is a vital part of working life, and if your staff use Respiratory equipment (RPE) as part of their work equipment, it is in your interest that respirators work properly and fit correctly. The Health & Safety Executives (HSE) guidance note HSE 282/28 promotes the proper use of respiratory equipment, and Fire Coral LTD’s face-fit testing ensures that every staff member is trained and masks are correctly fitted.




If your company handles dangerous chemicals and materials such as asbestos, the COSHH (Control of Substances Hazardous to Health) Regulations state Face-Fit tests are required when selecting RPE equipment for employees.



The HSE guidance note HSE 282/28 (paragraphs 9 & 10) informs companies about the correct use and fitting of RPE. Although only a guide, if this information is adhered to correctly, your company will be well within the law regarding respirators.

Qualitative Face Fit Testing Firm In Cambridgeshire



Disposable face masks, half masks and full-face masks are all required to have face-fit tests this includes all filtering face pieces and negative pressure full- face masks, power- assisted full face masks plus self-contained and air fed breathing apparatus. The importance with all facemasks is the correct fit to the face to prevent the inhalation of particles.

Cambridgeshire Face Fit Testing



A set of exercises under the simulation of everyday work and movement determines correct use and fit. There are 7 exercises which each staff member should complete, each lasting for 1 minute. If one of the exercises is a fail, the whole test needs to be re-taken. Each member of staff should have 10 minutes allocated to complete the whole range of exercises.

On Site Face Fit Testing Companies In Cambridgeshire



It is recommended by HSE 282/28 that the test exercises should be undertaken whilst performing movements such as walking on a treadmill, stepping motions on a stepper or cycling on an exercise bike. This should provide a simulation of physical work, which the mask wearer may be echoing in their daily work duties.

Book an asbestos training course with Fire Coral LTD in Cambridgeshire. Book now and receive a special rate. We can tailor a training package to your company needs not matter how many staff you require to be trained and face-fit tested. For more information, contact Fire Coral LTD today.

About Face Fit Testing

Face Fit Testing is a method that is used to identify how fitting a facepiece matches an individual. An inappropriate facepiece will substantially reduce the needed protection, so it is required to meet the safety criteria.

Furthermore, there are two types of Face Fit Testing - qualitative and quantitative. Qualitative method is specifically designed for testing of filtering facepieces (disposable masks) and half masks but not full face masks, as it is based on tasting or smelling a bitter, sweet or odorous compound. Whereas quantitative is designed for all types of masks and is also known as Fit Factor. It is based on numerical calculations of the efficiency of the fit.

About Cambridgeshire

Cambridgeshire is a former United Kingdom Parliamentary constituency. It was a constituency of the House of Commons of the Parliament of England then of the Parliament of Great Britain from 1707 to 1800 and of the Parliament of the United Kingdom from 1801 to 1885. It was represented by two Knights of the Shire until 1832, when the number of members was increased to three. It was divided between the constituencies of Chesterton, Newmarket and Wisbech in 1885. The parliamentary county was again reconstituted in 1918. In 1983, when the redistribution of seats took place on the basis of the expanded post-1974 Cambridgeshire, the constituency was divided between the new constituencies of North East Cambridgeshire (including a small part of Peterborough), South East Cambridgeshire and South West Cambridgeshire (including a minority of territory from the former Huntingdonshire). The historic county of Cambridgeshire. (Although Cambridgeshire contained the borough of Cambridge, which elected two MPs in its own right, this was not excluded from the county constituency, and owning property within the borough could confer a vote at the county election.